e
5.4 Changing colour strips of the sensor unit
The sensor unit can be adapted to match the colour of the wall using the col-
our strips supplied.
Remove sensor unit carefully from the mounting bracket (8).
Remove front cover (6) by lifting at the back of the sensor unit.
Attach the desired colour strips to the sensor unit.
When attaching the colour strips to the sensor unit, make sure that no
sensor is covered.
Fasten transparent front cover to the sensor unit.
Press sensor unit onto the mounting bracket (8).
6 Appendix
6.1 Technical data
Sensor unit
Battery type
Recommended battery type
Battery service life
Sound pressure at a distance of 1 m
Radio frequency
Range
Dimensions (W x H x D)
Degree of contamination
Power control unit
Rated voltage, 3phase
Rated current, 3phase
Conductor cross-section, 3phase
Rated voltage, 1phase
Rated current, 1phase
Conductor cross-section, 1phase
Energy consumption
Degree of contamination
Rated surge voltage
Operating temperature
42
AA/LR6 Alkaline
Duracell Ultra Power (MX1500)
3 ... 5 years
70 ... 75 dB (A)
10 ... 100m, depending on building structure
125 x 17 x 45mm
5 x 2.5 mm²
+5 ... +35°C
Ball pressure test
Creep resistance (PTI)
Number of switching operations
Dimensions (L x W x H)
Degree of protection
Standard
Potential-free contacts
Rated voltage
Rated current
6.2 Troubleshooting
Power supply to the cooker is switched off.
Cause 1: Battery level of the sensor unit is too low. Battery display (7) flashes.
Replace batteries.
Cause 2: Mounting position of the sensor unit is wrong and the status LED (5)
flashes yellow (●●●).
Check mounting position of the sensor unit and adjust if necessary (Figure
6).
2.4 GHz
Cause 3: Radio connection is interrupted and status LED (5) flashes blue (●).
Establish radio connection manually in setting mode 2 (see Manual commis-
sioning).
2
Cause 4: Power control unit is overheated and status LED (5) flashes blue
(●●●).
400 V
Let the device cool down for a while. If it occurs again, contact an electri-
3 x 16 A
cian.
Cause 5: Problem with the sensor unit and status LED (5) flashes yellow (●●).
230 V
Check batteries or have sensor unit checked.
1 x 25 A
Cause 6: Problem with the sensors and status LED (5) flashes yellow (●).
Clean sensor unit and sensors carefully.
3 x 6 mm²
4 W
2
4 kV
e
100 °C
175 ... 400
approx. 6000
239 x 113 x 42 mm
IP20
IEC/EN 60730-1: Type 1.B
DIN EN 50615
DC 3 ... 24 V
max. 10 mA
43