Information For Electricians; Installation And Electrical Connection - hager WXH20 Serie Mode D'emploi Et Instructions De Montage

Masquer les pouces Voir aussi pour WXH20 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

e
AUX1 / AUX 2
System status
Option 1:
AUX1
AUX2
In1
Out 1
Out 2
If a 1 signal is present on the AUX1 output, an alarm
In2
message is displayed.
+ 5 V
Output
Input
Option 2:
AUX1
AUX2
In1
Out 1
In2
Out 2
If a 1 signal is present on the AUX2 output, a normal
cooking situation is displayed.
+ 5 V
Output
Input
:
Option 3
AUX1
AUX2
If a 1 signal is present on the AUX2 output and on the
Out 1
In1
In2
Out 2
AUX2 output, a service technician must be called.
*AUX1 and AUX2 are switched in series. The second potential
*
carrying wire must be insulated according to the installation regula-
+ 5 V Input
Output
tions.
Option 4:
AUX1
AUX2
In1
Out 1
In2
Out 2
Both AUX outputs can be interconnected using an exter-
nal logic and are used for evaluation of all options.
Output
+ 5 V
Output
+ 5 V
Input
Input
&
≥1
Table 4: Connection possibilities for AUX outputs
32

5 Information for electricians

5.1 Installation and electrical connection

Connect power control unit
DANGER!
ç
Touching live parts can result in an electric shock.
An electric shock can be lethal.
Disconnect the connecting cables before working on the device
and cover all live parts in the area!
(12)
(13)
(11)
(16)
Figure 3: Mounting power control unit
(11) Connection socket for water leakage sensor
(12) Casing cover for power control unit
(13) Fastening screws for casing cover
(14) Device screws for flush-mounted/hollow-wall box (not included in scope
of delivery)
(15) Cut-out for flush-mounted installation
(16) Cooker supply cable (not included in scope of delivery)
(13)
(14)
IN
(15)
IN
5 x 2,5 mm
2
e
OUT
33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wxh21 serieWxh200Wxh202

Table des Matières