hager WXH20 Serie Mode D'emploi Et Instructions De Montage page 18

Masquer les pouces Voir aussi pour WXH20 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

e
(17)
(18)
L
IN
L
OUT
L
IN
L
OUT
L
IN
L
OUT
(20)
(11)
Figure 4: Connection assignment 3-phase
(27)
L OUT
X
(28)
L
IN
N
IN
(21)
N
OUT
Figure 5: Connection assignment 1-phase
(17) Connecting terminal for external signal generator (AUX)
(18) Connecting terminal L1
(19) Connecting terminal L2
(20) Connecting terminal L3
(21) Connecting terminal N
(22) Connecting terminal PE
(23) Entry for cooker supply cable
(24) Auxiliary cut-out for surface mounting
(25) Strain relief
(26) Connection cable 3-phase for cooker/hob (not included in scope of delivery)
(27) Connecting terminal L OUT
34
(19)
(25)
OUT
5 x 2,5 mm
2
(10)
PE
(24)
PE
N
N
(23)
(21)
(22)
(22)
PE
(29)
(28) Connecting terminal L IN
(29) Connection cable 1-phase for cooker/hob (not included in scope of delivery)
(26)
Figure 6: Connecting terminal (AUX) for external signal generator
When connecting a single hob the connecting terminals L2 and L3 are to
be assigned.
When connecting a single hob, the free, third wire must be insulated ac-
cording to the installation regulations.
The N-conductors are connected to the distribution terminals supplied
(only 3-phase variant).
The earthing conductors are connected to the distribution terminals supplied.
The power control unit must be positioned in such a way that all cables are
freely exposed, the device is protected against mechanical damage and is
not exposed to any humidity or additional heat.
The power control unit should be positioned ideally in a wall box on the
wall or below the corresponding kitchen base unit.
Switch off circuit breaker for cooker/hob.
Unscrew fastening screws (13) of the casing cover (12) and remove the
cover.
Fix cut-out for the flush-mounted installation (15) or surface-mounted instal-
lation (24).
Unscrew device screws (14) of the flush-mounted/hollow-wall box.
Insert cooker supply cable (16) into the power control unit (23).
Position the power control unit over the flush-mounted/hollow-wall box and
fasten with the device screws (14).
AUX1