e
Mounting water leakage sensor
The leakage sensors are positioned under the sink, in the area of the dishwash-
er and in additional places where water leakage is likely.
(28)
(9)
Figure 8: Mounting water leakage sensor
(30) Water leakage sensor plug
(31) Water leakage sensor
(32) Connection socket for additional water leakage sensors
Insert plug of the leakage sensor (30) into the jack on the power control
unit (11).
Place the water leakage sensor (30) under the dishwasher (Figure 8).
Optional: Insert additional water leakage sensor into the plug (32) of the
front sensor (30).
5.2 Automatic commissioning
A functional test should be carried out by an electrician after installation.
The default settings of the cookguard are to be used for the initial setup. If the
mounting height of the sensor unit or the dimensions of the cooker/hob vary
from the standard values (Figure 7), then the commissioning must be performed
manually (see Manual commissioning).
38
(11)
(30)
(32)
(31)
Performing a functional test
Switch on cooker/hob with highest power.
With an induction cooker a suitable pot must be used for commissioning.
Keep the operation button (3) pressed for 5 s.
The power supply to cooker/hob is interrupted. Cooker/hob is switched off.
Check if cooker/hotplate is switched off.
Switch off cooker/hob manually via the corresponding hotplate switch.
With the cooker/hob switched off, press the operation button (3) once.
The power supply to the cooker/hob is switched on again. Cookguard is
ready for operation. Status LED (5) flashes once in green.
5.3 Manual commissioning
Manual commissioning is necessary if the cooker was replaced, the cooker
dimensions and mounting height of the sensor unit vary from the standard values
(Figure 7) or if false alarms occur too frequently.
Manual commissioning is performed via four setting modes on the sensor unit:
-
Mode 1: Set alarm limit
-
Mode 2: Set radio connection
-
Mode 3: Calibrate cooker type
-
Mode 4: Set AUX connection
The setting modes can be changed successively or individually.
Keep the operation button (2) pressed for 5 s.
Setting mode (1) is active. Status LED (5) lights up white.
Press operation button (3) repeatedly until the desired setting mode is
called up.
WARNING!
ç
Risk of accident!
If the setting of the alarm limit is too high, the detection of
hazards is delayed.
Do not set alarm limit higher than 8 during the installation!
Setting alarm limit
The alarm limit is preset to 6 in default state. This means that the sensor unit is
mounted at a height of 50 ... 60 cm (wall mounting) or 55 ... 65 cm (mounting un-
e
39