4.4

Connecting the control system with EGC box

4.4.1

Connecting the control system

The cable harness contains the connection cables of the signal box, the drum motor and the rinsing pump.
These connection cables have to be connected, the EGC box is already connected.
 I
How to proceed:
► Connect the three connectors of the cable harness to the sockets of the control system and the
capacitor box. Hand-tighten the union nuts.
– The connections are designed to prevent reverse polarity.
– First flood the container with water, then connect the control system to the mains voltage/power
supply.
4.4.2

Connecting the EGC box

Integration of the filter system into the EGC network is optional and not necessary for operation. (→ Easy
Garden Control System (EGC))
The Connection Cable EGC cable is required for connecting the EGC box.
The correct fastening of the plug connector is important for a secure connection and an interference-free
EGC network.
How to proceed:
 I, L, M
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 18 lb-in (2.0 Nm)).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor
EGC and secure it with the two screws (max. 18 lb-in (2.0 Nm)).
– Ensure that the terminal resistor EGC instead of an EGC connection cable is installed on EGC-
OUT of the last unit in the EGC network to ensure that the EGC network is closed off properly.
– The scope of delivery of InScenio EGC Controller includes a terminal resistor EGC.
4.4.3

Connecting an additional EGC compatible unit

An additional EGC compatible unit can be connected to the EGC box.
► Ensure the correct connection. (→ Connecting the EGC box)
How to proceed:
 L, M
1. Remove the protection cap from EGC-OUT on the EGC box and fit the plug connector of the
EGCConnection Cable.
2. Remove the protection cap from EGC-IN on the additional unit and fit the other plug connector of the
EGC Connection Cable.
3. Remove the protection cap from EGC-OUT of the additional unit, fit the terminal resistor and secure it
with the two screws (max. 18 lb-in (2.0 Nm)) or connect another EGC-compatible unit.