Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- EN -
3.2

Unit configuration

 C
Description
1
Container cover
2
Signal box with level detection device (3) and temperature probe (7)
• The signal box is connected to the control system (30, 32)
3
Level detection device
• Signals the water level in the filter system
4
Rollers for guiding the filter drum
6
Filter drum with 8 screen elements
• Screen elements for coarse dirt down to 60 µm in size, 30 + 150 µm also available as an option
7
Temperature probe
• monitors the water temperature
8
Air hose ∅ ⅜ in (∅ 9 mm)
9
Hel-X 13 biomedia in Moving Bed filter chamber
10
2 × outlet ∅ 4 in (DN 110)
11
Aerator rod
12
Meshed tube
• Prevents the Hel-X- biomedia from being flushed out
13
Rinsing pump for supplying the rinsing device (24)
14
1 × dirt outlet with slide valve ∅ 3 in (DN 75)
15
2 × adapter, 2 × 30° inlet bend with union nut
For connection of UVC clarifier Bitron to ∅ 1½ in (∅ 38 mm) connections (18)
16
Connection set for filter pumps
• 1 × hose connector ∅ 2 in (∅ 50 mm), 1 × union nut for hose connector, 1 × hose clip ∅ 1.6 ... 2.3 in
(∅ 40 ... 60 mm), 1 × flat gasket 2.2 × 1.7 × 0.1 in (56 × 43 × 3 mm)
17
1 × inlet ∅ 2 in (∅ 50 mm)
• For connecting a filter pump
18
2 × inlet ∅ 1½ in (∅ 38 mm), closed with sealing plugs
• For connecting an optional UVC clarifier Bitron
20
1 × optional inlet ∅ 2 in (∅ 50 mm)
• Must be cut out, if required (connection not included in the scope of delivery)
21
1 × coarse dirt outlet ∅ 4 in (DN 110)
22
Drum motor for filter drum
• The motor is connected to the control system (30, 31)
23
Dirt channel
• Collects the coarse dirt and rinsing water from the screen elements (6)
24
Rinsing device
• Sprays water at high pressure onto the screen elements (6) to rinse off the coarse dirt
25
Grease for the drum seal
27
Transition piece ∅ ⅜ in to ∅ ⅛ in (∅ 9 mm to ∅ 4 mm)
28
Y piece
29
2 × cable binder for fastening the air hoses to the Y piece
30
Control system with EGC box
• Allows integration with cables into an EGC network.
31
Plug for connecting the drum motor
32
Socket for connecting the signal box
33
Mains connection cable
34
Connector for rinsing pump
35
Fuse holder
• Fuse protection of the control system with safety fuse 5 × 20 mm, T16 A, 250 V
36
2 x cap, cap nut for fastening the EGC box
• Required for mounting the EGC box on the container wall
37
Capacitor box for the rinsing pump
38
Plug for connecting the control system (34)
39
Plug for connecting the rinsing pump
18