13.4 External sensors
13.4.1 Temperature sensor
Sensor
Combined pressure and
temperature sensor
13.4.2 Pressure sensor
Sensor
Pressure transmitter
13.5 Adapter
Adapter
Adapter for 1/4" NPT
13.6 Cable for sensors
Length
Description
[ft (m)]
Screened cable
6.56 (2.0)
Screened cable
16.40 (5.0)
13.7 Blanking flange
A blanking flange is used to blank off the opening when one of the
pump heads of a twin-head pump is removed for service to
enable uninterrupted operation of the other pump. See fig. 67.
Pump type
MAGNA3 D 65-150 F
MAGNA3 D 80-100 F
MAGNA3 D 100-120 F
Fig. 67 Position of a blanking flange
66
Measuring
Measuring
Type
range
range
[psi (bar)]
[°F (°C)]
0-232
14 to 248
RPI T2
(0-16)
(-10 to +120)
Measuring
Measuring
Type
range
range
[psi]
0-9
(0 - 0.6)
0-15
(0 - 1.0)
RPI
0-25
(0 - 1.6)
0-35
(0 - 2.5)
Product number
98344015
Product number
98374260
98374271
Product number
98159372
Transmitter
Power
output
supply
[mA]
[VDC]
4-20
12.5 - 30
Transmitter
Power
output
supply
[bar]
[mA]
[VDC]
4 to 20
12 to 30
14. Disposing of the product
This product has been designed with focus on the disposal and
recycling of materials. The following average disposal values
apply to all variants of pumps:
•
85 % recycling
•
10 % incineration
•
5 % depositing.
Dispose of this product or parts of it in an environmentally sound
way according to local regulations.
See also end-of-life information at
www.grundfos.com/product-recycling.
Process
Product
connection
number
G 1/2
98355521
Process
Product
connection
number
97748907
97748908
G 1/2
97748909
97748910