Télécharger Imprimer la page

Trix Class H6 Mode D'emploi page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Programming table of the most important CVs
CV
Designation
49
Expanded configuration
61
Acceleration time
in a signal block
62
Braking time
in a signal block
63
Noise volume
Blocked list: The following CVs must not be
changed under any circumstances: 43, 44, 45, 46, 47, 48, 56, 57, 58, 60, 66, 95, 113, 114, 115, 121
Meaning
Additional setting options.
Total value must be calculated.
Total value = value of bit0 + value of bit6
Bit
Function
0
Load regulation off
Load regulation active
1
Braking area: opposed polarity
DC operation off
Braking area: opposed polarity
DC operation on
5
No automatic
DCC speed level detection
Automatic
DCC speed level detection
Acceleration time from 0 to Vmax.:
Value * 0.869 in sec.
Braking time from Vmax. to 0:
Value * 0.869 in sec.
0 = soft, 1 = medium, 2 = loud
7, 9, 11, 13, 14, 23, 24, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42,
Area
0, 1, 2, 3,
32, 33, 34, 35
Val.
0
1
0
2
0
32
0 – 64
0 – 64
0, 1, 2
Factory setting
33
8
4
2
29