Replacing the dispensing unit chain
UN41-0527AN
For this operation, proceed as outlined below.
1) Unscrew the nut (A), loosen the screw (E) and remove
the casing (B).
2) Move the tensioner (C) and remove the chain (D).
CAUTION
The tensioner could move unexpectedly, causing in-
jury to the hands.
Proceed with the utmost caution.
Replacing the pinions of the dispensing unit
UN41-0767MP
English language
INFORMATION CONCERNING REPLACEMENTS
3) Fit the chain on the pinions and the tensioner.
NOTICE
Fit the chain with the joining link positioned as
shown in the figure.
4) Fit the casing (B), tighten the nut (A) and the screw
(E).