Parker TGE308 Notice D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN | Operating Instructions
Check well running of threads
There is a risk of threads seizing when a fi lter made of aluminium, steel or stainless
steel is stored.
▶ Make the same preparations as described in section "Preparations" on page 10.
▶ Open the fi lter at regular intervals, e.g. every 6 months.
▶ Check whether the threads are still suffi ciently greased and well running.
▶ Apply a thin coat of grease on the housing threads before assembly if necessary.
Use only TG 1 thread grease unless any other grease has been agreed upon in
the order!
▶ Connect both housing parts again.
▶ For ATEX-compliant fi lters:
Ensure conductivity, test and document it.
▶ Check the housing for tightness.
Disposing of fi lter elements
The fi lter element or cartridge might be contaminated by the fi ltered substances.
Heed the notes on hazardous substances for the fi ltered gas and applicable dis-
posal regulations when disposing.
You can obtain the waste code number for the used materials from the manufac-
turer.
TGE 308-318
Maintenance intervals and work
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tge318

Table des Matières