1.3.9 Parameters
System 1.1 and 1.2:
Select
to set the additional heat delay. See page 4. Press
>OK<.
Select
when charge pump RO1 is to start. Press >OK<.
Select
for pump RO1 to stop. Press >OK<. Press >ESC<.
Select
difference when pump RO1 is to stop. Press
Press >ESC<.
Select
ference when return pump RO2 is to start. Press
>OK<. Press >ESC<.
Select
for return pump RO2 to stop. Press >OK<. Press
>ESC<.
Select
ture at which the buzzer shall warn before the addi-
tional heat is activated. Press >OK<. Press >ESC<.
Select
for the two pumps. Press >OK<. Press >ESC<.
Select
when additional heat is to be activated. If
del<
is activated there is a start delay. Press >OK<.
Press >ESC<.
Select
when additional heat is to be deactivated. Press
>OK<. Press >ESC<.
System 2.1 and 2.2:
Select
to set the additional heat delay. See page 4. Press
>OK<.
Select >Add. Heat warn.(RW)<. Set the tempera-
ture at which the buzzer shall warn before the
additional heat is activated. Press >OK<. Press
>ESC<.
Select >Pump restart delay<. Set the restart delay
for the two pumps. Press >OK<.
Select
when charge pump RO1 is to start. Press >OK<.
Press >ESC<.
Select
TS2 at secondary tank top when pump RO1 is to
start. Press >OK<. Press >ESC<.
Select
TS3 at secondary tank bottom when pump RO1 is
to stop. Press >OK<. Press >ESC<.
Select
TS2 drops with the set value, the additional heat
source will be activated after the set delay. Press
>OK<. Press >ESC<.
System 3.1 and 3.2:
Select
temperature and the start temperature for pump
RO1. Press >OK<. Press >ESC<.
Select
when the heat source is to be activated. Press
>OK<. Press >ESC<.
Select
when the heat source and pump RO1 are to be
deactivated. Press >OK<. Press >ESC<.
Select
BT drops by the set value, pump RO1 will stop.
Press >OK<. Press >ESC<.
Select
after which pump RO1 is to stop. Press >OK<.
Press >ESC<.
Select
set, after which charging is to restart. The orange-
coloured symbol shows the delay. Press >OK<.
Press >ESC<.
8
>Dynamic Recharge Delay<
>Charge temp.
(BT)<. Set the temperature
>Charge Hyst. (CH)<
and set the hysteresis
>Charge Diff.
(CD)<. Set the temperature
>Return Diff.
(RD)<. Set the temperature dif-
>Return Hyst.
(RH)<. Set the hysteresis
>Add. Heat
warn.(RW)<. Set the tempera-
>Pump restart
delay<. Set the restart delay
>Add. Heat act.
(RA)<. Set the temperature
>Add. Heat off
(RO)<. Set the temperature
>Dynamic Recharge Delay<
>Main tank
(MT)<. Set the temperature
>Tank 2 top
(ST)<. Set the temperature
>Tank 2 bot.
(SB)<. Set the temperature
>Add.Heat offset
(RAO)<. If temperature
>Boiler temp
(BT)<. Set the heat source
>Tank 2 top
(ST)<. Set temperature ST
>Tank 2 bot.
(SB)<. Set temperature SB
>Charge Hyst.
(CH)<. When temperature
>Pump pause
(PO)<. Here the delay is set,
>Charge pause
(CRD)<. Here the delay is
Press >OK<.
>OK<.
1.5.1 Anti-block pr...
>dyn.rech.
1.5.3 Antifreeze pr...
Press >OK<.
1.6 Monitoring
1.6.6 Pump moni-
to...
1.6.5 Sensor balan.... Long piping and other factors may distort measured
1.7 Login
1.7.1 Manual mode
If the professional mode is not exited actively, the SmartBio auto-
matically displays the hydraulic system after the display shut-off time
and the value of the login code is reset to 1.

Malfunction

The screen on top right shows the red
points out a notification or an operating malfunction. Press
1.10 Service Wizard
When
>Safety function<
Bio indicates that a protective function has been triggered.The mes-
sage is only active until normal operation has been restored.
SmartBio communicates malfunction processes in plain text. The
Service Wizard indicates the possible causes of malfunctions on
the basis of the detected symptoms and thus supports immediate
detection of deficiencies.
For example
. Press
>Next.<
The Service Wizard helps detect possible causes of malfunctions.
>Possible reasons:< >Cable/connection<
pressing
>OK<
The Service Wizard provides the trouble-shooting instructions. Press
to go through all check-points.
>Next<
Finally the repair information appears. Perform the appropriate repair
work. Press
After elimination of the malfunction, the plant screen without the red
attention triangle appears again on the display and automatic mode
is continued.
System 4:
Select >Pump restart delay<. Set the restart delay
for the two pumps. Press >OK<. Press >ESC<.
Select
>Domestic Water
perature DW in the domestic hot water tank when
charge pump RO2 is to stop. Press >OK<. Press
>ESC<.
Select
>Tank set-point
SP at main tank top. Press >OK<. Press
Select
>DW Hyst.
has fallen by the value DH, pump RO2 will start.
Press >OK<. Press >ESC<.
Select
>Charge Diff.
TS1 has exceeded temperature TS2 by the value
CD, pump RO2 will start. Press >OK<. Press
>ESC<.
Select
>Charge Hyst.
TS1 has fallen by the value CH, pump RO2 will
stop. Press >OK<. Press
>Protective
functions<. Press >OK<. Select
blocking<. Press >OK<.
The pumps can be moved daily to prevent them
from getting blocked. This function is not acti-
vated as long as the outputs are activated in
normal operation. Determine the time of the day
and the operating period. Press >ESC<. Select
>Antifreeze
protect.<. Press >OK<.
If the function is activated and the temperature
falls below the adjusted
the corresponding pump is switched on. . In hy-
draulic systems 1.1, 1.2 and 4 sensor TS3 can be
activated for optional temperature display. Press
>ESC<
twice. Select >Monitoring<. Press >OK<.
Select
>Pump
monitoring<. Press >OK<.
Here the function is activated. Set temperature
changes and monitoring time for error messages.
Press >OK<. Press >ESC<. Select
ancing<. Press >OK<.
variables. Here an offset value can be entered for
each sensor. If a measured value is e.g. 80°C and
the display shows 85°C, the offset value is -5°C.
If a measures value is for e.g. 80°C and the display
shows 75°C, the offset value is +5°C. Press
twice. Select >Login<. Press >OK<.
Select
>Manual
mode<. Press >OK<.
In manual mode the individual outputs can be
activated for testing purposes, e.g. to check that
a pump is working properly. Manual mode can
only be exited by pressing >ESC<.
appears in the display, this is a message. Smart-
>MO2: Breakage of sensor on TS1<
.
>OK<
or
. Select
. Press
>Exit<
>OK<
to leave the Service Wizard.
>Exit<
(DW)<. Set the tem-
(SP)<. Set the temperature
>ESC<.
(DH)<. When temperature DW
(CD)<. When temperature
(CH)<. When temperature
>ESC<
twice. Select
>Anti-
>Min.temperatur<
value,
>Sensor bal-
>ESC<
triangle which
>Attention<
>OK<
appears. Select
. Select a cause by
>Sensor<
.
.