LED P1
Off
1 fast red flash each second
1 fast green flash each sec-
ond
2 fast green flashes + pause
for 1 second
1 fast red flash followed by 1
fast green flash + 1 second
pause
1 fast green flash followed by
1 fast red flash + 1 second
pause
2 fast red flashes + pause for
1 second
Red LED on
Red LED on
1 red coloured short flash
every 0.5 seconds
1 green coloured short flash
every 0.5 seconds
1 red+green coloured short
flash every 0.5 seconds
LED P2
Off
On
Series of quick flashes, from
1 to 4
5 quick flashes
1 slow flash
3 slow flashes
5 slow flashes
Status
Anomaly or control unit in full standby mode
The control unit has no memorised wireless
devices configuration (factory condition)
Automation moving or in test:
The control unit has at least one accessory
device installed.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was
successful and all devices respond correctly
and have their batteries charged.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was
successful and all devices respond correctly
but at least one has an almost empty
battery.
The automation is neither moving nor in
test. The control unit has at least one ac-
cessory device installed; the last manoeuvre
was successful and all devices respond cor-
rectly, but the control unit did not receive
a good radio signal from at least one of
them.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was
successful and all devices respond but at
least one of them has an almost com-
pletely empty battery and at least one
did not send a good radio signal to the
control unit.
The automation is neither moving nor in test.
The control unit has at least one accessory
device installed; the last manoeuvre was
successful but at least one device on the
network did not respond.
The automation is moving or in test. The
control unit has at least one pair of photo-
cells installed.
Network learning procedure by new control
unit (cloning) in progress; the control unit is
waiting for the address of the old network
The control unit is detecting the old devices
Network learning procedure by new (clon-
ing) in course; the control unit has received
the address of the old network
Status
All OK
Memorisation in Mode 1
Memorisation in Mode 2
Cancellation OK
Wrong command
Memorisation OK
Cancellation OK
Action
Automation could be in standby; press and release a key to see
if the led lights up or flashes; if this has no effect make sure there
is power supply; check that the fuses are not blown; if this is the
case, verify the cause of the fault and then replace them with oth-
ers of the same value
Normal operation; the control unit does not have any wireless de-
vice installed and is ready to learn a wireless network.
Normal operation
Normal operation
Check the battery charge level on the wireless devices; activate the
test procedure (paragraph 8.2 )
Limited radio communication; if possible, search for a better posi-
tion for the device
Check the battery charge level on the wireless devices; activate the
test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better posi-
tion for the device
Check the battery charge level on the wireless devices; activate the
test procedure (paragraph 8.2 ).
Limited radio communication; if possible, search for a better posi-
tion for the device
Normal operation if there is an obstacle between at least one pair
of photocells, or at least one photocell is not responding. Check
the battery charge level on the wireless devices; activate the test
procedure (paragraph 8.2 ). It is possible that radio communication
is at its limit; if possible, search for a better position for the device.
There may also be a radio interference problem.
Normal operation
Normal operation
Normal operation
Action
No memorisation in progress.
During memorisation in mode 1, it is normal for it to take a maxi-
mum of 10 s.
During memorisation in mode 2, it is normal for it to take a maxi-
mum of 10 s.
Completion of deletion of a transmitter.
A command has been received from an unmemorised transmitter
Memorisation completed successfully
Completion of deletion of all transmitters.