Output table CNPa for 240 strokes/min
Type
Minimum pump
capacity
at maximum back
pressure
bar
l/h
concept
plus
1001
10
1.0
1602
16
1.5
1003
10
2.7
0705
7
5.2
0312
3
11.4
0223
1.5
19.9
concept
metering pumps with self-bleeding dosing head SER***
plus
1003
10
2.4
0705
7
4.2
0311
3
11.0
0220
1.5
18.6
* Suction lifts with a filled suction line and filled liquid end
** Priming lifts with clean and moist valves, feed chemical water (20 °C), at 100 % stroke length,
max. stroke rate, free outlet or opened bleed valve and correctly installed piping.
**The given performance data constitutes guaranteed minimum values, calculated using medium
water at room temperature. The bypass connection with a self-bleeding dosing head is 6x4 mm.
Minimum pump
capacity
at medium back pres‐
sure
ml/
bar
l/h
strok
e
0.07
5.0
1.3
0.10
8.0
1.9
0.19
5.0
3.5
0.36
3.5
5.9
0.79
1.5
14.4
1.38
1.0
23.4
0.17
5.0
3.6
0.29
3.5
5.2
0.76
1.5
17.6
1.29
-
-
Con‐
nector
size
outside Æ
x inside Æ
ml/
mm
stroke
0.09
6x4
0.13
6x4
0.24
6x4
0.41
6x4
1.00
8x5
1.63
8x5
0.25
6x4
0.36
6x4
1.22
8x5
-
8x5
Technical data
Suc‐
Pri‐
Max.
tion
ming
priming
lift*
lift**
pres‐
sure on
the suc‐
tion side
m WS
m WS bar
6.0
1.8
8
6.0
2.0
8
5.0
2.5
5
4.0
3.0
3
2.0
2.0
1
1.5
1.5
0.5
5
1.8
5
4
1.8
3
2
1.8
1
1.5
1.8
0.5
51