Robert Juliat 900 SNX Dossier Technique page 19

Projecteurs de decoupes msr 1200/2500w reamorcage a chaud
Table des Matières

Publicité

MAINTENANCE
REFLECTOR.
- Disconnect from the mains.
- Open the bonnet of the lamp house.
- Take out the lamp.
(Refer to section A - 7).
- Clean the reflector 1 with a soft dry cloth.
ASPHERIC LENS.
- Unscrew the lock 2 .
- Take out the lens holder set 3 .
- Clean the lens with a soft dry cloth.
- Remount the lens holder set.
- Clean in the same way, the lenses in the zoom.
Check the lamp position.
SPARK-GAP.
- Disconnect from the mains.
- To exceed to the spark-gap, open the trap door at the back of the
lighting unit.
- Unsrew the nut a , while holding in place the counter-nut b .
- Then, unscrew the counter-nut b .
- Adjust, with a 2,5 Allen key, the upper electrode c to
1 mm from the electrode.
- Tighten the counter-nut b and the nut a .
• The adjustment is made, when manufactured.
Interfere only in case of a faulty starting.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
DECOUPES MSR 1200W / 2500W
Disconnect from the mains before any servicing.
Service only by qualified technician.
MINI = 7mm.
900 SNX
2
3
Section B - 1
1

Publicité

Table des Matières
loading

Table des Matières