Robert Juliat 900 SNX Dossier Technique page 29

Projecteurs de decoupes msr 1200/2500w reamorcage a chaud
Table des Matières

Publicité

3.3. The off command is given, but the lamp
stays on.
Green &
red LED :
off
Green &
red LED
on.
4 . NON-FUNCTIONING DIAGNOSIS FOR THE SHUTTER :
1.1 The shutter command is given, but no
action.
1.2 . The shutter only excepts an up command,
does not except an down command.
1.3 . The shutter reacts badly, and the motor
runs continuous.
1.4. The shutter act in a saw-tooth movement
on a fluent command.
1.5. Shutter action is delayed to command.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
DECOUPES MSR 1200W / 2500W
message unchanged.
message unchanged.
New shutter level
not displayed.
New shutter level
displayed.
The shutter does
not react or reacts
badly.
The shutter level is
correctly displayed.
Transmission Data error :
connection failure : check the wiring.
( refer to sections A - 7 & A - 14 ).
connection damaged or :
( refer to sections A - 7 & A - 14 ).
Command link error :
Digital - refer to 3.1.
Analog - refer to 2.
Shutter cable demaged :
Check cable.
Faulty power supply :
Change CAD :
( Refer to section C - 10 )
Motor demaged : Change the
whole shutter unit.
( refer to section C - 7 )
Error on the Shutter unit :
Change the whole shutter unit.
( refer to section C - 7 )
900 SNX
Section B - 11
Resend the
"LAMP OFF"
command.
Resend the
"LAMP OFF"
command.
resend the
resend the
level
level
command.
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.

Publicité