By
turning the open-end wrench clockwise (viewed from above),
move the actuator into the required position.
Fig. 19:
Place open-end wrench on the hexagon
Open-end wrench
for turning the
actuator
Fig. 20:
Turning with open-end wrench
24
Open-end wrench
Open-end wrench
for securing the
nipple
english
Type 2000/2002
Assembly
8.4.
pneumatic connection
Danger!
risk of injury from high pressure in the equipment!
•
Before dismounting pneumatic lines or valves, turn off the pres-
sure and vent the lines.
Warning!
risk of injury from unsuitable connection hoses!
Hoses which cannot withstand the pressure and temperature
range may result in hazardous situations.
•
Use only hoses which are authorized for the indicated pressure
and temperature range.
•
Observe the data sheet specifications from the hose
manufacturers.
for control function i – danger if control pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
•
To ensure a controlled restart, first pressurize the device with
control pressure, then switch on the medium.