Input Data
MPP voltage range
Input voltage range (at 1000 W/m²/14°F in an open circuit)
Max. input current (MPP1/MPP2)
(MPP1 + MPP2)
Max. short circuit current of solar modules (I
Max. backfeed current from AC grid
Output Data
Nominal output power (P
nom
Max. output power (+104°F)
Max. output power (+140°F)
Phases
Nominal grid voltage
Operating range AC voltage
Adjustment range for grid voltage
Max. continuous output current at V
AC recommended min. overcurrent protection
Max. output residual current per duration
Nominal frequency
Total harmonic distortion
Power factor (cos phi)
General Data
Maximum efficiency
CEC efficiency
Cooling
Protection class
Dimensions h x w x d
Weight (full/lite version)
Permissible ambient temperature
) (MPP1/MPP2)
SC PV
1)
)
nom
10.0-3 208-240
9995 W
9995 W
at 208 V
8000 W
at 220 V
8600 W
at 240 V
8600 W
at 208 V
at 220 V
at 240 V
at 208 V
27.7 A
at 220 V
26.2 A
at 240 V
24.0 A
at 208 V
35.0 A
at 220 V
35.0 A
at 240 V
30.0 A
< 1.5%
at 208 V
96.50%
at 220 V
at 240 V
96.50%
Controlled forced-air ventilation
90.4/89.5 lbs. (41.0/40.6 kg)
-40°F to +140°F (-40°C to +60°C)
12.0-3 208-240
300–500 V DC
200–600 V DC
25.0/16.5 A
41.5 A
37.5/24.8 A
2)
0.0 A
11,995 W
11,995 W
8000 W
8600 W
8600 W
3 ~ NPE
120/208 V
127/220 V
120/240 V
-12 to +10%
60–152 V/104–288 V
33.3 A
31.5 A
28.9 A
45.0 A
40.0 A
40.0 A
43.1 A/158.4 ms
50/60 Hz
< 1.75%
3)
0–1 ind./cap.
97.00%
96.50%
96.50%
NEMA 4X
28.5 x 20.1 x 8.9 in.
725 x 510 x 225 mm
59