Fronius Datamanager 2.0

Controls, Con-
nections, and In-
dicators on the
Fronius Dataman-
ager 2.0
No. Function
(1)
(10)
(9)
(8)
IP switch
For changing the IP address:
Switch position A
Specified IP address and opening the WLAN Access Point
Fronius Datamanager 2.0 uses fixed IP address 169.254.0.180 for a direct con-
nection to a PC via LAN.
If the IP switch is set to position A, an Access Point for a direct WLAN connec-
tion to Fronius Datamanager 2.0 is also opened.
Access data for this Access Point:
Network name: FRONIUS_240.XXXXXX
Key: 12345678
Fronius Datamanager 2.0 can be accessed:
-
via DNS name "http://datamanager"
-
via IP address 169.254.0.180 for the LAN interface
-
via IP address 192.168.250.181 for the WLAN Access Point
Switch position B
Assigned IP address
Fronius Datamanager 2.0 operates using an assigned IP address (factory set-
ting DHCP dynamic).
The IP address can be set at the Fronius Datamanager 2.0 website.