Values Displayed
Output power (W) - depending on the device type (MultiString), the individual output
in the NOW Menu
power values for MPP Tracker 1 and MPP Tracker 2 (MPPT1 / MPPT2) are displayed af-
ter the Enter key
AC reactive power (VAr)
Grid voltage (V)
Output current (A)
Grid frequency (Hz)
Solar voltage (V) - U PV1 of MPP Tracker 1 and U PV2 of MPP Tracker 2 (MPPT1/
MPPT2), if MPP Tracker 2 is activated (see 'The Basic menu' - 'The Basic menu entries')
Solar current (A) - I PV1 of MPP Tracker 1 and I PV2 of MPP Tracker 2 (MPPT1/
MPPT2), if MPP Tracker 2 is activated (see 'The Basic menu' - 'The Basic menu entries')
Time/date - time and date on the inverter or in the Fronius Solar Net ring
Values Displayed
Amount of energy fed (kWh/MWh)
in the LOG Menu
amount of energy fed into the grid during the observation period.
After pressing the Enter key
Tracker 2 (MPPT1/MPPT2) are displayed, if MPP Tracker 2 is activated (see 'The Basic
menu' - 'The Basic menu entries')
Due to the variety of different monitoring systems, deviations may exist between the read-
ings of other measuring instruments and the readings from the inverter. Only the readings
of the calibrated meter supplied by the electricity company are relevant for determining
the energy supplied to the grid.
Maximum output power (W)
highest amount of energy fed into the grid during the observation period.
After pressing the Enter key
MPP Tracker 2 (MPPT1/MPPT2) are displayed, if MPP Tracker 2 is activated (see 'The
Basic menu' - 'The Basic menu entries')
Earnings
money earned during the observation period
As was the case for the output energy, readings may differ from those of other instru-
ments.
The setting of the currency and charge rate is described in the "'Energy yield' subitem in
the Setup menu".
The factory setting depends on the country setup.
CO2 savings
carbon dioxide saved during the observation period
The CO2 factor setting is described in the "'CO2 factor' subitem in the Setup menu" sec-
tion.
Maximum mains voltage (V) [phase - neutral or phase - phase display]
maximum mains voltage measured during the observation period
The individual mains voltages are listed after the Enter key
is pressed
the individual output powers for MPP Tracker 1 and MPP
the individual output powers for MPP Tracker 1 and
is pressed