Fronius Symo Serie Instructions De Service page 63

Masquer les pouces Voir aussi pour Symo Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fronius Symo
Input Data
MPP voltage range
Input voltage range (at 1000 W/m²/14°F in an open circuit)
Max. input current
Max. short circuit current of solar modules (I
Max. backfeed current from AC grid
Output Data
Nominal output power (P
nom
Max. output power (+104°F)
Max. output power (+140°F)
Phases
Nominal grid voltage
Operating range AC voltage
Adjustment range for grid voltage
Max. continuous output current at V
AC recommended min. overcurrent protection
Max. output residual current per duration
Nominal frequency
Total harmonic distortion
Power factor (cos phi)
General Data
Maximum efficiency
CEC efficiency
Cooling
Protection class
Dimensions h x w x d
Weight
Permissible ambient temperature
Permissible storage temperature
Permissible humidity
Noise emission
Protection Devices
Reverse polarity protection
Anti-islanding function
Arc detection/interruption
) (MPP1/MPP2)
SC PV
1)
)
nom
at 208 V
at 220 V
at 208 V
at 220 V
at 208 V
at 220 V
at 208 V
106–132 V/183–229 V
at 220 V
112–140 V/194–242 V
at 208 V
at 220 V
at 208 V
at 220 V
Controlled forced-air ventilation
-40°F to +140°F (-40°C to +60°C)
-40°F to +158°F (-40°C to +70°C)
15.0-3 208
325–850 V DC
340–850 V DC
325–1000 V DC
47.8 A
45.7 A
49.5/37.5 A
2)
0.0 A
15,000 W
15,000 W
6600 W
3 ~ NPE
120 V/208 V
127 V/220 V
-12 to +10%
41.6 A
39.4 A
60 A
50 A
67.7 A/153 ms
60 Hz
< 3.5%
3)
0–1 ind./cap.
97.30%
96.50%
NEMA 4X
28.5 x 20.1 x 8.9 in.
725 x 510 x 225 mm
78.7 lbs. (35.7 kg)
0–100%
72.5 dB(A) (ref. 1pW)
Integrated
Integrated
Integrated
63

Publicité

Table des Matières
loading

Table des Matières