STORAGE, TRANSPORTATION AND DISPOSAL
The drive stops during opening
and performs independent
reverse movement when
closing; the indicator shows error
number 'E1'
The drive stops during opening
and completes independent
reverse movement when
closing; the indicator shows error
number 'E2'
The drive performs independent
reverse movement when
closing; the indicator shows error
number 'E1'
The drive does not start working,
when command is given; the
indicator shows error number 'E4'
The drive does not start working
or spontaneously stops, when
command is given; the indicator
shows error number 'E5'
The drive does not start working,
when command is given; the
indicator shows error number 'E6'
Error number 'E8' is shown on the
indicator when the final positions
are being set
10. STORAGE, TRANSPORTATION AND DISPOSAL
The product shall be stored in its packaging in closed dry spaces. Do not expose to atmospheric
precipitation or direct sunlight. Shelf-life is 3 years from the manufacture date. Transportation
can be performed using all types of covered ground vehicles, with measures to prevent shock
and movement inside the vehicle.
Disposal of the product shall comply with the regulatory and legal requirements on
recycling and disposal, valid in the user's country. The product does not contain
substances, posing danger to life and health of people, and environment.
30
fAULT
Obstacle, resulting in force
(power consumption) excess,
is found
Photocells are activated
Optical sensors of safety margin
are activated
Error occurred during phototest
Tripping occurs based on the
signal on input STOP
The drive overheats due to
excessive heating or excessively
intensive operation
Either support is not installed
on the rail, or the support is
installed at a larger distance
from the OPEN position, than
required
LEVIGATO DRIVES (LG SERIES)
POSSIBLE REASON
|
LEVIGATO ANTRIEBE (SERIE LG)
RECOMMENDATIONS
Make sure that there are no obstacles
and check the correct operation
of the door (absence of 'jamming'
during operation; correct balance
etc.); if necessary, increase the
permissible force values
(functions 'P5'–F1 and 'P5'–F2)
Check the performance of
photocells, replace, if necessary;
check the selected photocells mode
in the menu
Check the performance of
the safety margin, replace the
failing components, if necessary;
check the selected safety margin
mode in the menu
Check the performance of photocells,
replace, if necessary; check the
selected photocells mode in the menu
Check the working condition of the
safety elements, connected to the
STOP input (or crossover presence),
replace them, if necessary
Take a break in drive operation
for 10 ... 15 minutes, sufficient for
the internal elements to cool down;
do not allow operation of the drive
with the intensity exceeding the one,
stated above
Set the support at a distance ~ 20 mm
from the OPEN position and repeat
the final positions adjustment
procedure
|
COMMANDES LEVIGATO (SERIE LG)