ADjUSTMENT
Enter the programming mode
(similar to items 1.1–1.5 from
24.1
Table 6). Select program 'P6'
and function 'F2'
'01 ...99'—drive speed values.
'01'—minimum speed value,
24.2
'99'—maximum speed value.
Default value—'99. '
P6–F3—Setup of drive acceleration time during
25
opening
Enter the programming mode
(similar to items 1.1–1.5 from
25.1
Table 6). Select program 'P6'
and function 'F3'
'00 ... 05'— values of drive
acceleration time during
opening.
25.2
'00'—minimum value,
'05'—maximum value.
Default value—'02. '
P6–F4—Setup of drive deceleration time during
26
opening
Enter the programming mode
(similar to items 1.1–1.5 from
26.1
Table 6). Select program 'P6'
and function 'F4'
'00 ... 05'— values of drive
acceleration time during
opening.
26.2
'00'—minimum value,
'05'—maximum value.
Default value—'02. '
P6–F5—Setup of drive acceleration time during
27
closing
Enter the programming mode
(similar to items 1.1–1.5 from
27.1
Table 6). Select program 'P6'
and function 'F5'
LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
'00... 05'—values of drive
acceleration time during
closing.
27.2
'00'—minimum value,
'05'—maximum value.
Default value—'03. '
P6–F6—Setup of drive deceleration time during
28
closing
Enter the programming mode
(similar to items 1.1–1.5 from
28.1
Table 6). Select program 'P6'
and function 'F6'
'00... 05'—values of drive
acceleration time during
closing.
28.2
'00'—minimum value,
'05'—maximum value.
Default value—'03. '
P7—SAfETy ELEMENTS SETUP
P7–F1—Setting the operational mode of
29
photocells
Enter the programming mode
(similar to items 1.1–1.5 from
29.1
Table 6). Select program 'P7'
and function 'F1'
'no.'—photocells are off;
'CL.'—photocells are set to
work during door closing,
29.2
'OP.'—photocells are set to
work during door opening.
Default value—'CL.'
30
P7–F3—PHOTOTEST mode setup
Enter the programming mode
(similar to items 1.1–1.5 from
30.1
Table 6). Select program 'P7'
and function 'F1'
'no.'—PHOTOTEST is off
'on.'—PHOTOTEST is on.
30.2
Default value—'no. '
|
COMMANDES LEVIGATO (SERIE LG)
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lg-800-868Lg-1000f-868Lg-1200-868Levigato lg serie

Table des Matières