MOUNTING
Use multicore cable with double insulation for electric connection of the drive system compo-
nents. The parameters of the electric cables used (section, number of wires, length etc.) should
comply with the connection diagram, device power, laying distance, way of laying, ambient
conditions.
Do not perform any electric connections while laying the electric cables. Make sure, that the
cables are isolated and therefore not live.
Prior to mounting:
• determine the place, where each component of the drive system will be installed.
Fig. 2 presents a typical diagram of the garage door automation. Together with the user,
determine the places for the installation of the control devices.
• Determine the scheme, according to which all the electric devices of the drive system will
be connected.
• Lay the electric cables to the places, where the drive system components are to be
installed, complying with the regulations in force.
• Remove unnecessary parts (ropes, angles etc.) and disconnect all the unnecessary
equipment.
4.
MOUNTING
4.1
DRIVE RAIL AND DRIVE MOUNTING
Recommended mounting procedure:
• determine and mark the mounting line in the middle of the door (fig. 3). If mounting
cannot be performed in the middle of the door, it acceptable to mount at the distance
not exceeding 100 mm to left or to the right from the middle of the door.
• Install the door bracket using eight 6.3 × 20 screws (fig. 4). Drill Ø 5 mm holes in the door leaf
metal.
Y
Limit the drilling depth during drilling. Do not allow through drilling of the door leaf.
• Install the rail fastening bracket on the wall on the drive rail using two 'M6' × 12 bolts
and two M6 nuts (fig. 5A). The product construction allows turning of the bracket by
90 ° in relation to the rail during installation (fig. 5B), e.g., to mount the rail on the ceiling
without suspension strips.
• Mark the rail fastening bracket installation area on the wall (fig. 6 ). The clearance between
the rail and the maximum (top) spot of the door movement should be 20–50 mm.
• Fasten the rail fastening bracket on the wall (fig. 7).
Y
Fixings (dowels, anchors), required to install the rail, should be selected to comply with the
type of construction surfaces present (material and thickness of the wall or ceiling). They
are not included in the kit. The fittings should be able to bear the weight of the rail with the
drive fitted and resist the force required to open and close the door. Beware of wear and
deformation, which will occur in time.
• Install the brackets, fastening the rail to the ceiling, on the drive rail (fig. 8).
• Install one bracket at the distance 180 ... 220 mm from the rail edge (fig. 9).
• Install the second bracket in ensuring position which ensures the best stability of the rail.
For example, at 1 / 3 from the door opening (fig. 10).
LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
|
COMMANDES LEVIGATO (SERIE LG)
15