TESTING AND COMMISSIONING
P8–F4—Switching the signal lamp operating
mode to light lamp operating mode
This option allows you to operate a connected
36
external light lamp, instead of the signal lamp;
the operation of the light lamp is set according to
the algorithm, similar to that of the built-in drive
internal light
Enter the programming mode
(similar to items 1.1–1.5 from
36.1
Table 6). Select program 'P8'
and function 'F4'
'no.'—output 'SL / LL' works in
the signal lamp mode,
'on.'—output 'SL / LL' works in
36.2
the external light lamp mode,
Default value—'no. '
7.
TESTING AND COMMISSIONING
This is an important stage of drive system installation. The test is performed as follows:
• make sure that the full scope of the instructions in section 1. 'General warnings and safety
rules' and other requirements of the manual are complied with.
• Ensure stable and secure mounting of the drive and the guide rail.
• Unblock the drive (section 4.2. 'Manual unblocking'). Manually open and close the door
several times. Make sure, that there are no points of increased resistance to movement, and
there are no assembly and setup defects. Return to the blocked state.
• Perform the full OPEN-CLOSE cycle. Make sure, that the door moves in the required
directions, the leaf of the door moves smoothly. At the end of opening and closing the
door moves slowly.
• Check the guide belt tension degree and tighten if necessary (fig. 19).
• Make sure that the integrated LED backlight is functioning. It is active when the door is
moving and for a set time after the door stops.
• Check the correct working of the connected control devices (control buttons, remote
controls).
• Check the correct working of each connected safety and alarm device (photocells,
movement stop devices, lamps etc.). Check the photocells for the absence of interaction
with other devices, to do so—close the optical axis: first close to TX-photocell (transmitter),
then close to RX-photocell (receiver) and then in the middle, between the two photocells.
Make sure that in all cases the drive properly reacts to the activation of photocells (during
closing the door stops and then fully opens).
LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
P0—RESETTING TO DEfAULT SETTINGS
(EXCEPT REMOTE CONTROLS, RECORDED IN THE DRIVE MEMORy)
P0–F0—Resetting to default settings (except
37
remote controls, recorded in the drive memory)
Enter the programming mode
(similar to items 1.1–1.5 from
37.1
Table 6). Select program 'P0'
and function 'F0'
The display will show
37.2
symbols '- -'
Press
and hold it
for about 5 secs, until a dot
appears on the display, this
means, that all drive settings
37.3
are to default
(except remote controls,
recorded in the drive
memory)
To exit the programming
37.4
mode press
times or wait for 15 seconds
|
COMMANDES LEVIGATO (SERIE LG)
three
27