ELECTRICAL INTERfACES
CONTACT
Alarm lamp or illumination lamp connection output (see fig. 24). By default, the output is set to
SL / LL
work in the SL lamp mode (signal lamp). In settings (section '6. Adjustment') you can select the
output operation mode
Input for step-by-step control devices with NO contact.
Sequence of commands OPEN—STOP—CLOSE—STOP—OPEN...
SBS
Several control units are connected in parallel
Safety devices input STOP with NC contact.
S
The activation results in immediate stop of movement or preventing any movement beginning.
Several safety devices are connected consecutively
+ 12 V
Accessories output. Nominal power voltage 12 V DC / max. 120 mA
+ 24 V
Accessories output. Nominal power voltage 24 V DC / max. 120 mA
GND
General output
Optical sensors connection input or input of resistive margin of safety (8.2 kOhm). In settings
(section '6. Adjustment') the following can be selected, depending on the connected safety
device: resistive sensor (fig. 28) or optoelectronic sensor (fig. 27).
SE
The contact of the door with an obstacle during closing (activation of a sensor) causes the door
to stop moving and then fully open
Photocells connection input with NC contact. By default, the input is set to the activation of
photocells during closing (they are not active during opening). The activation of photocells
during closing results in an immediate stop, followed by full opening, or preventing further
closing beginning.
PH1
When setting the photocells to operate only during opening (section '6. Adjustment') the
activation of the photocells results in immediate tripping.
Several safety devices are connected consecutively
The output for automatic operation test (PHOTOTEST) of photocells, connected to output PH1.
The operation of the photocells is checked before movement by short-term disconnection and
then reconnection of the power to the photocells transmitter. Photocells connection diagram—
PH.T
fig. 26. In settings (section '6. Adjustment') the activation of the corresponding menu option is
performed
Connection input of the antenna screening conductor
Connection input of the antenna signal conductor
The connector (fig. 29) used to connect the 24 V DC / 1.2 Ah battery. The battery gives the
opportunity to open the door in the emergency mode (in case of supply voltage disconnection).
The full charge time of the battery is ~ 48 hours
The operation of the devices is shown by LEDs (fig. 30).
LED
command from remote control board
PH1
safety device—photocells (input 'PH1')
S
safety device—STOP (input 'S')
SBS
command to open, stop, close (input 'SBS')
Y
The state of LEDs, when a command is not given, is shown in bold.
18
INDICATION DESIGNATION
LEVIGATO DRIVES (LG SERIES)
DESCRIPTION
|
LEVIGATO ANTRIEBE (SERIE LG)
DOES NOT
ILLUMINATES
ILLUMINATE
not given
is given
was
was activated
not activated
was
was activated
not activated
not given
is given
|
COMMANDES LEVIGATO (SERIE LG)
Table 4
Table 5