Centre of the garage door

Eye protection goggles should be worn for overhead work.
All available barriers / locks should be deactivated to avoid damage
to the door.
To avoid serious injuries, remove all cables and chains connected to the
door before installing the door opener. The door opener should be
mounted at a height of at least 2.10 m above the ground.
First, mark the centre line of the door (1). Draw a line to the ceiling
starting from this point.
For installation on the ceiling, draw another line to the centre of the
ceiling (2) perpendicular to the door starting from this line.
Length approx. 2.80 m.
8

Mounting header bracket

NOTE: Mount the rail max. 50mm above the top edge of the door.
Depending on the door type, the top edge of the door is lifted by a
few cm during opening.
A. Wall fastening:
Minimum space requirement above the door: 100 mm
Mount header bracket (6) centrally on the vertical centre line (2); thereby
its lower edge lies on the horizontal line. Mark all holes for the header
bracket. Pre-drill holes with 4.5 mm diameter and fasten the header
bracket with wood screws (16).
NOTE:
In case of mounting on a concrete slab / concrete header, the provided
concrete plugs (18) and screws (16) should be used. Drill hole size in
concrete: 8 mm.
B. Ceiling suspension:
Minimum space requirement above the door: 35 mm
Draw vertical centre line (2) further up to the ceiling and about 200 mm
along the ceiling. Attach header bracket (6) centrally on the vertical
marking up to 150 mm removed from the wall. Mark all holes for the
header bracket. Drill holes with 4.5 mm diameter and fasten the header
bracket with wood screws (16).
9

Attaching drive to header

It may be necessary to place the drive temporarily higher, so
that the rail does not hit the springs in multi-piece doors.
The drive must either be well supported (ladder) or held firmly
by a second person. Put drive head on garage floor under the lintel
bracket. Lift rail up till the holes of the fixing part and the holes of the
lintel bracket are aligned.
Insert screw (10) through the holes and secure with nut (11).
10

Hang opener

1. Fully open the door, put down door opener on the door (Fig. A).
Lay a piece of wood / cardboard on the marked spot (X).
2. The mounting bracket must be mounted so far back that the
carriage is not obstructed. The carriage can pass through below
the bracket partially, but not the door arm. Mounting at the very
back (Fig. B) is ideal.
3. Bend ceiling fixtures (4) in such a way that they lie flat against
the ceiling. Depending on how large the distance to the ceiling is,
none, one or two of the support brackets are to be mounted
(Fig. C1, C2 and C3).
4. Mark the boreholes on the ceiling. Pay attention to the same lateral
distance along the drawn centre line in each case.
5. For concrete ceilings, boreholes with 8 mm diameter are drilled into
the ceiling and dowels (18) used. Then, the ceiling fixtures are fastened
in the ceiling with hexagon wood screws (16). While mounting on the
wooden ceiling: fasten only on the supporting parts of the wooden
ceiling. Drill boreholes with 4 mm diameter and use hexagon wood
screws (16).
6. Place mounting bracket (5) around the rail, then align to the ceiling
fixture and bolt them together.
After the installation of the garage door drive, particularly using a rail
extension, if the rail is observed to be bent up or down for more than 5
cm during the beginning or end of the travel as well as while encounte-
ring an obstacle, a central suspension must be provided by the customer.
For this, please contact the manufacturer of the garage door drive.
Pay attention to a horizontal course of the rail along the
ceiling. The distance can be adjusted by the given hole
spacing. Protruding ends of the ceiling fixture can be
reduced if necessary.
11

Mounting door bracket

Installation in sectional or one-piece doors:
The door bracket (7) has multiple mounting holes. Attach door bracket
top centre on the inside of the door as shown. Mark holes and screw
door bracket.
Mounting heights:
1. One-piece or sectional door with a guide rail:
distance to door top edge 0-100 mm.
2. Sectional door with two guide rails:
distance to door top edge 100-130 mm.
NOTE:
The attachment point on the door must be the frame or a stable place
on the door panel. If necessary, drill through and screw (not included)
together as shown in Fig. B.
12

Attaching door arm on the trolley

The straight door arm is already pre-assembled.
Recommended installation:
The trolley can be separated from the drive by pulling the red handle
and manually pushing towards the door. When the door is closed,
fix the curved door arm (3) on the door bracket with the bolt (14) and
secure with cotter pin (15). Connect straight and curved door arms
together flush with an overlap of 2 holes with screw (12) and secure
with nut (13). Choose the holes in such a way that the door arm
stands at an angle of about 30-40°.
NOTE:
The curved door arm can be omitted, if the door fitting has been
attached at the far upper edge of the door.
Mount the release handle of the emergency release at a
height less than1.80 m. Attach the yellow label regarding the
release of the garage door opener (sticker) on the cord of the
door handle.
13

Electrical connection

In order to avoid personal injury and damage to the device,
the door opener should be operated only if such an instruction
is explicitly stated in this manual. The power plug must
always be freely accessible for the purpose of disconnecting
the mains supply. Electrical installations may only be under-
taken by an authorized electrician.
14
Installation of photocells
After installing and adjusting the door opener, photocells can be
installed (terminals 2 + 3). The instructions for installation are included
in the scope of delivery of the light barrier and must be followed.The
optional photocells ensure that the door is open, or remains
open, if people, especially young children, are in the door area. By
means of the photocells, a closing door is opened or an open
door is obstructed from closing, if a person located in the door area
interrupts the sensor beam.
Photocells are particularly recommended for families with young
children.
Connecting the illuminated push button
14
(Optional accessories)
All wall-mounted switches or buttons should be installed in
sight of the door outside the door or door rail area at a
height of 1.5 metres. In addition to these switches, the
warning sign for the protection of children should be affixed.
(Optional accessories)