Safety in relation to coolant R290
•
This device contains the coolant R290. R290 is a coolant that complies
with the relevant European Directives. Never perforate the coolant
circuit. R290 is flammable (GWP 3)!
•
Never use substances other than those recommended by the
manufacturer for the defrosting process.
•
This device must be used and stored in a room that does not contain
sources of ignition, such as open flames or gas and electrical devices
in operation.
•
Do not perforate any of the components of the cooling circuit and do
not set light to the device.
•
If the device is installed, working or stored in an un-ventilated you must
take measures to prevent fire or explosions caused by leaked coolant.
Ensure that there are absolutely no sources of ignition (such as fire,
heaters, sparking electrical equipment, lit cigarettes, etc.) in the
same room!
•
The device must be stored in such a way that mechanical defects
are prevented.
•
Do not install, operate or store the device in a room smaller than 15m².
•
R290 is odourless, which means that you cannot smell leaks!
•
Persons working on the cooling circuit must be in possession of the
correct qualifications that state the person in question is competent to
use coolant in accordance with a special evaluation that is recognised
by the sector association.
•
The repairs must be executed on the grounds of the recommendations
of the manufacturer of the device. Maintenance and repairs that require
the assistance of other qualified persons must be executed under
supervision of someone who is specialised in the use of
flammable coolant.
29