Thermal monitor FK 4000
Safety
Scope of supply
(5)
Fig.1
Procedure
1.
2.
3.
4.
WARNING! Work that is not carried out correctly can cause serious damage
and injury. The actions described below may ONLY be carried out by skilled,
trained technicians! Observe and follow the "Safety rules" in the "Operating
Instructions" manual for the power source.
WARNING! An electric shock can be fatal. Before opening up the machine:
-
Shift the mains switch of the power source into the"O"position
-
Unplug the power source from the mains
-
Affix an easily readable and understandable warning sign to
prevent machine from being switched back on.
Upon opening up the machine discharge any live components, if available
(e.g. electrolytic capacitors).
(3)
(2)
(6)
(1)
(4)
Thermal monitor adapter kit
Drain off the collant
Remove housing shell and side panel
Remove coolant hose (A) from
copper connecting tube of cooler and
water return pulg-type connector and
dispose
Slide the brass receptacl e (2) over
the copper connecting tube on the
cooler
Note! Fit the brass receptacle (2) so that both bores are Ø=2,7 mm toward the
cooler.
1)
1 off
(2) 1 off
(3) 1 off
(4) 1 off
(5) 1 off
(6) 2 off
(7) 5 off
(7)
(A)
Fig.2
Side view
1
TP 592
Brass receptacle
Interconnecting cable
Molex pin housing
Hose 8x13mm (0,5 m)
Clamps 1lug 16,8
Cable ties