Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
TILT ALARM FUNCTION
After POWER ON the laser automatically activates the TILT function. The TILT LED (12) is flashing duri-
ng the activation procedure. When it is completed (after 90 sec. approx.) the LED is illuminated.
If the laser is disturbed rotation stops and the laser beam and TILT LED (12) will flash.The laser will not
re-level automatically.
If required the self-levelling procedure can be re-activated by pressing button (10).
To quit the TILT function press button (11).
If the laser is disturbed due to a positional change of the tripod it will automatically self-level itself
(within the self-levelling range of 5°), a height offset can occur. This will be avoided by using the TILT
function. The use of this function ensures that the laser is shut off even within the self-levelling range if
the laser is disturbed. Switch the unit on and wait until the self-levelling procedure is completed.
VIBRATION-WIND-SECURITY FUNCTION (V-W-S)
Press button (18) to activate the V-W-S. The V-W-S LED (19) is illuminted and the TILT LED (12) starts
flashing. When the V-W-S LED (19) and the TILT LED are both illuminated the V-W-S is activated. The
V-W-S function automatically activates the TILT function. This function allows continuous operation
during periods of vibration and wind. If a significant movement occurs the laser stops rotating and the
TILT LED (12) and the laser beam start flashing. Press the V-W-S button (18) to cancel. Press the V-W-S
button (18) once more for re-activation.

SCANNING MODE

Press button (1) to select the scanning function. The scan angle is 180°.
Press button (1) to change the scan angle:
180° -> 90° -> 45°-> 10° -> 45° -> 90° -> 180°.
Press button (2) to orientate the scan line in a clockwise direction and button (3) for anticlockwise.
Press button (7) to quit the scanning function.
REMOTE CONTROL SHIELD
Press button (16) to switch off the remote control. The remote control LED (17) is illuminated to
confirm the activation. It may be necessary to switch off the remote control to avoid interference with
other instruments working on the same site.
The remote control can only be switched off on the instrument keypad.
Press key (16) to re-activate the remote control.
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Flg 260va-green

Table des Matières