OPERATION
Set-up the laser on a flat and even surface or mount onto a tripod.
Press the ON/OFF button (8) to powe on the laser.
After POWER ON the laser automatically self-levels. The laser beam and the TILT LED (12) flash indi-
cating that the automatic self-levelling procedure is activated. This self-levelling procedure may take up
to 90 sec. When completed the TILT LED (12) is illuminated. The laser starts rotating at 800 rpm. If the
TILT LED (12) continues to flash and the alarm beep sounds the laser was most likely set up outside its
self-levelling range of ± 5°. Re-position the instrument on more even surface.
VERTICAL USE
• Unfold the datum point on the integrated floor mount and set up the laser in its vertical (lay-down)
position.
• The laser automatically self-levels in this position.
• Set the ciruclar bubble as accurately as possible by using the two thumb screws. This ensures that
the instrument is set within its self-levelling range and the rotating beam is centered over its datum
point.
All functions are identical to those in the horizontal position with following exceptions:
In SOPE the X axis can be set manually, the Z axis is automatically self-levelled. The TILT and / or V-W-S
function can be activated. If a slope has been set in the X axis and the laser is temporarily switched off,
the axis will retain its original position when the laser is switched on again.
In MAN mode both (X and Z) axes can be set manually.
The TILT and V-W-S function cannot be activated. If a slope has been set in the X and Z axes and the
laser is temporarily switched off, the X axis will retain its original position when the laser is switched on
again but the Z axis will self-level.
Set up the laser in the horizontal position first to re-set the self-levelling position.