LOCK (MANUEL MODE)
Keep the buttons
ATTENTION:
The self-levelling mode is powered off, the laser is in manual mode. Keep both buttons pressed again to
quit the manual mode.
ALIGNMENT OF THE LASER
Banking
The laser is equipped with a digital vial that shows the alignment of the transvese axis. The laser is set
up correctly if the vial is centered.
Display indication
The laser is out of tolerance on the left side - correct the set up.
Display indication
The laser is perfectly levelled; most accuracte performance.
Display indication
The laser is out of tolerance on the rigtht side - correct the set up.
STAND-BY MODE
Press the button to start the stand-by mode. The values set will be stored, the laser stops working.
The laser dot is turned off and the
the working mode.
20
and
pressed until
laser start point LED
If the laser is in stand-by mode for more than 30 min. it will automatically power off.