3.5.10 Insert The Capillar Trap And Lower Section; 3.5.11 Check And Carry Out Commissioning - Berbel Ergoline 2 Manuel D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation

3.5.10 Insert the capillar trap and lower section

After the installation, the parts lying inside should be re-fitted.
Insert the Capillar Trap into the mounting slot in a bow
movement with both hands.
Push the Capillar Trap upwards until it latches into place.
Insert the lower section horizontally into the device until
it reaches the rear stop.
Pivot the lower section upwards until both magnetic
fasteners can be heard to click into place.
Check that the lower section is inserted correctly and is
held by the retaining magnets.
138
Close the front panel.

3.5.11 Check and carry out commissioning

ATTENTION!
Risk of disruptions due to moisture in the device!
If the device is moved from a cold environment into a hot
one, condensation may form inside.
Wait about 2-3 hours before bringing the device into
service.
Check that the mains plug is freely accessible or that
an all-pole isolating device (min. 3 mm contact gap) is
present.
Check that the mains cable and the electrical connection
cable are not kinked, crushed or damaged.
Ensure that air outlets are not closed or covered.
With recirculated air devices: Make sure that the
ventilation slots are free.
Check the correct functioning of the device.
"4. Operation" (page 139).