PR electronics 6350 Manuel Du Produit page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LERBAKKEN 10, 8410 RØNDE DENMARK.
Hazardous area: Zone 0
Sensor Circuit (terminals 41...44, respectively 51...54):
in type of protection intrinsic safety Ex ia IIC, Ex ia IIIC or Ex ia I, with following maximum values:
U
= 5.7 V; I
= 8.4 mA; P
o
o
Current Measurement Input Circuit (terminals 13 and 14, respectively 23 and 24):
in type of protection intrinsic sapfety Ex ia IIC, Ex ia IIIC or Ex ia I, only for connection to a certified
intrinsically safe circuit, with the following maximum values (per circuit):
U
= 30 V, I
= 140 mA, P
i
i
Revision date:
2014-12-15
Hazardous area: Zone 1
CH1
41
14
42
13
43
12
44
11
CH2
51
21
52
22
53
23
54
24
6350B
CH1
41
14
42
13
43
12
44
11
CH2
51
21
52
22
53
23
54
24
6350B
CH1
41
14
42
13
43
12
44
11
CH2
51
21
52
22
53
23
54
24
6350B
= 12 mW; C
= 40 µF; L
o
o
= 1 W, C
= 0 nF, L
= 0 mH
i
i
i
Version Revision
V2R0
WWW.PRELECTRONICS.COM
Non Hazardous area
In type of protection intrinsic safety Ex ib IIC,
only for connection to a certified intrinsically
safe
fieldbus,
with
values:
U
= 30 V; I
= 250 mA; P
i
i
T
 85 °C: Temperature class T4
a
T
 75 °C: Temperature class T5
a
T
 60 °C: Temperature class T6
a
or for connection to a certified intrinsically
safe circuit in accordance with FISCO, with
following maximum values:
U
= 17.5 V; I
= any P
i
i
T
 85 °C: Temperature class T4
a
T
 75 °C: Temperature class T5
a
T
 60 °C: Temperature class T6
a
The effective internal capacitance and the
effective internal inductance of the Fieldbus
input circuit are:
C
= 2 nF; L
= 1 µH.
i
i
= 200 mH.
o
6350104-FR
6350QI01
following
maximum
= 5.32 W.
i
= any.
i
Page:
3/3
21

Publicité

Table des Matières
loading

Table des Matières