SECTION 5
MAINTENANCE
3. Remove the electrical tape which secures the pilot arc (red) cable to the main
power cable. This exposes the wire splice. Remove the heatshrink tubing
from pilot arc cable to expose the pilot arc knife-splice connection.
Disconnect the connection.
Main Power Cable
Electrical Tape
Wire splice
Pilot Arc Cable
Heatshrink Tubing
Knife-splice connection
145