Paramétrage via le jeu de données PROFIdrive 47
6
Lire ou écrire les paramètres via le jeu de données 47
0 0
Commentaires sur
le bloc fonction
6.4.2
Caractéristiques techniques PROFINET pour MOVIPRO
56
Write service: x2h, fixed setpoint: P160, index 8489d = 2129h
Wiring of FB:
"Drive_IO_Address": (INT)
"bService":
(BYTE) Read: 01h;
"bAxis":
(BYTE) Sub address/SBUS address of lower-level MC07
"wParameterindex":
(WORD) Parameter index => "MC07 Communication" manual
"wSubIndex":
(WORD) MOVILINK subindex = 0
"dwWriteData":
(DWORD) Parameter data for WRITE service
"InstanzDB_SFB52(BLOCK_DB) Instance DB for the SFB52
"InstanzDB_SFB53(BLOCK_DB) Instance DB for the SFB53
"fActivate"
(BOOL) Activation bit
"fBusy":
(BOOL) Parameter service is active
"fDone":
(BOOL) Parameter service was executed
"bError"
(BYTE) No error = 0; S7 error = 1; TimeOut = 2;
"dwData":
(DWORD)bError = 0 => Parameter value after READ service
Fichier GSD pour PROFINET :
Désignation du module de configuration
Jeu de données supporté
N° d'emplacement supporté
Code fabricant
ID du profil
Longueur max.
1) AAAMMJJ correspond à la date
Input address of the process data =>Hardware config.
Write 02h,
MOVILINK error = 3
bError = 1 => S7 error code
®
SDC
GSDML-V2.1-SEW-MOVIPRO-AAAMMJJ.xml
SEW-MOVIPRO
Index 47
Recommandé : 0
10A hex (SEW-EURODRIVE)
0
240 octets
Manuel MOVIPRO® SDC avec interface PROFINET
volatile writing 03h