GYS GYSFLASH 4.12 Manuel D'utilisation page 9

Masquer les pouces Voir aussi pour GYSFLASH 4.12:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Translation of the original instructions
Step
1
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery...)
Step
: Recovery (
2
Damaged elements recovery due to an extended deep
discharge algorithm.
3
Step
: Test
Sulfated battery test.
Step
4
: Desulfation (
Battery desulfation algorithm.
• Estimated charge time
Battery capacity
Charging time 20% >>> 80%
If the motorbike is fitted with a 12V plug, the GYSFLASH 4.12 can charge the battery via this plug with the CAN-BUS
system, without switching the dashboard on. In this setup, connect the cigarette lighter adapter on the charger and on
the motorbike's 12V socket then follow the «start up » procedure on the previous page. In certain cases, it is possible
that the charge will only start 2 minutes after performing the connections.
• Protections :
The GYSFLASH 4.12 has several features to protect it against short-circuits or polarity inversion. It has an anti-spark
feature which prevents sparks whilst connecting the device to the battery. This charger has double insulation and is
compatible with vehicle's onboard electronics.
The GYSFLASH 4.12 is fitted with an integrated temperature probe that ensures that the charging current is adapted to the
ambient temprature to prevent internal electronics' overheating.
TROUBLESHOOTING
Symptoms
1
The indicator
blinks.
2
The indicator
is on.
The indicator
stays on even after pres-
3
sing the
button.
4
The indicator
blinks.
5
The indicator
stays on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 4.12
0.5A
2A)
15.8V)
2Ah
8Ah
2h
6h
• Polarity inversion
• Battery voltage is too high
• Clamps in short-circuit
Charge failure, battery non recoverable.
Thermal protection.
Charger in sleep mode.
Charge interrupted by pressing the
button.
Step
5
: Charge (
0.8A
Fast charge with maximum current that can reach 80% charge
level.
Step
: Absorption (14.4V or 14.7V with
6
Constant voltage charge to reach a 100% charge level.
7
Step
: Floating charge (13.6V)
Maintains battery charge level at its maximum.
15Ah
18Ah
11h
3h
Causes
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery and press
charge.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press the button
charger to exit sleep mode.
Press
4A)
AGM option)
50Ah
90Ah
8h
14h
Remedies
to restart a
or connect a battery to the
again to restart the charge.
EN
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Flash 4.12Gysflash 1.12

Table des Matières