MaiNTeNaNCe aNd repair

6.1 safety instructions
Danger!
Risk of injury from improper repair work!
▶ Maintenance may only be carried out by authorized technicians with
the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
8
Nut
Observe torque!
(see table below)
O-ring
Plastic ring
(optional)
The rotational position of the coil on the valve body is arbitrary.
Wrench size
SW 14
SW 22
7
spare parTs
Caution!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries and
damage the device and the surrounding area.
▶ Use only original accessories and original spare parts from Bürkert.

7.1 Ordering spare parts

Nut
Coil set
Fittings set
10
english
Coil installation torque
5 Nm
15 Nm
Nut and coil set can be ordered
completely by quoting the iden-
tification number of the device
(see type label).
Fittings set on request.
english
6.2 installation of coil
Warning!
Escaping medium!
When a sticking nut is loosened, medium may escape.
▶ Do not tighten sticking nut any further.
Overheating, risk of fire!
Connection of the coil without pre-assembled fittings will result in
overheating and destroy the coil.
▶ Connect the coil with pre-assembled fittings only.
Electric shock!
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock!
▶ During installation insert the plastic ring (optional) into the body
journal. The plastic ring must not project over the octagonal nipple.
▶ Check protective conductor contact after installing the coil.
6.3 Malfunctions
If malfunctions occur, check whether
the device has been installed according to the instructions (correct
direction of installation),
the connection has been made properly,
the device is not damaged,
all screws have been tightened,
the voltage and pressure have been switched on,
the pipelines are clean.
If the magnet is not attracting
Possible causes:
• Short circuit or coil interrupted,
• Core or core area dirty.
After occurrence of an external fire
• After an external fire, check the equipment and safety shut-off device.
• If there is visible damage, replace safety shut-off device.
english
8

TraNspOrT, sTOrage, dispOsal

note!
Transport damages!
Inadequately protected equipment may be damaged during
transport.
• During transportation protect the device against wet and dirt in
shock-resistant packaging.
• Avoid exceeding or dropping below the allowable storage
temperature.
Incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature: -30 ... +80 °C.
Damage to the environment caused by device components
contaminated with media.
• Observe applicable regulations on disposal and the environment.
9