Preparation For Storage - IMER RD 75 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE
the filter cannot be cleaned it must be replaced every 200 h.
8.
Assemble the elements [(d) and (e) Fig. 33] and put them back in place;
9.
Put back the wing nut [(c) Fig. 33];
10. Replace the cover [(b) Fig. 33] and correctly tighten the wing nut [(a) Fig. 33].
NOTE
Use only genuine parts.
9.4. REPLACING THE FUEL FILTER (DIESEL)
Replace the fuel filter [(a) Fig. 34], located at the bottom of the tank, every 1000 operating hours.
NOTE
This operation should be performed by the dealer of by the nearest After Sales Service.
9.5. REPLACING THE FUEL PIPE
Replace the fuel pipes every 2 years or every 1500 operating hours.
In case a leak is detected on fuel pipes, replace them at
NOTE
This operation should be performed by the dealer of by the nearest After Sales Service.
9.6. INSPECTION OF BOLTS, SCREWS AND NUTS
Tighten bolts and nuts when they are loose.
Make sure there is no oil leak.
Make sure there is no water leak on hydraulic fittings.

10. PREPARATION FOR STORAGE

□ There must be no water left in the pump for long periods of time. Deposits or minerals can settle
down on parts of the pump and damage it.
46
once.
WARNING

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Swt 75dSwt 120dJet100d