12.3.
Routing hoses and electrical cables in cabinet-mounted compressors
Route the hose and electrical cables through the opening in the rear wall of the cabinet for
compressor models with a dryer.
Risk of damage to pneumatic components.
Air hoses must not be broken.
13. ELECTRICAL CONNECTION
The product is delivered with a cord equipped with a plug with earthing pin.
With cabinet-mounted compressors, route the power cord through the opening in the back wall
of the cabinet.
Keep the socket easily accessible to ensure that the device can be safely disconnected from the
mains.
Connection to the power distribution cabinet must be max.16 A
Risk of electric shock.
It is necessary to follow all local electro technical regulations. The mains voltage
and frequency must comply with the data stated on the device label.
Risk of fire and electric shock.
Electrical cord must not be broken.
Risk of fire and electric shock.
Electrical cable must not be in contact with hot compressor components.
Connect the pin for equipotential bonding 6 mm
(1) to the electrical circuit using the defined
method
under
regulations
The socket for equipotential bonding (2) is an
accessory and is not provided in the basic
package
Mount the connector of the grounding conductor on the door and screw on the cabinet.
Power supply connection
Supply voltage
230V/50 (60) Hz
400V/50 (60) Hz
13.1.
Connecting a compressor not installed in a cabinet
Insert the mains plug into a rated mains socket.
The compressor is ready for operation.
NP-DK50 4VR 50, DK50 2x4VR 110-MD-6_01-2022
valid
electrical
engineering
Electric wire type
3Gx1.5x4000
5Gx1.5x4000
Fig. 11 :Equipotential bonding
32
INSTALLATION
01/2022