You can set coaxitron protocol with D3 and D4 in S1.
S1-D3
OFF
ON
OFF
ON
You can set CVBS output with D1 in S2.
S2-D1
CVBS Output
OFF
When WDR is on, CVBS output will be disabled.
ON
CVBS output will be displayed always. (DWDR)
Setting the Dome Camera Address (ID)
For a trouble-free function, each dome camera must have a unique address (ID). The
factory default setting is 1.
Refer to '3.10 Dome Communication' section of the Manual for detailed information.
Connections
Connecting to the RS-485
The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS-485 half-duplex serial communications signals.
Connecting HD Output connector
Connect the HD output (BNC) connector to the video input.
Connecting CVBS Output connector
Connect the CVBS output (BNC) connector to the video input.
10
S1-D4
OFF
OFF
ON
ON
HD-TVI OUTPUT
Hikvision-C
Pelco-C
Reserved
Reserved
AHD OUTPUT
ACP-PTZ
Reserved
Reserved
Reserved