Section 3 - Operation; Controls - Miller Spectrum 2050 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour Spectrum 2050:
Table des Matières

Publicité

3-1. Controls

1
8
1
Gas/Air Pressure Gauge
2
Gas/Air Pressure Control
3
Output Control
Use control to select cutting output in am-
peres. Gas/air automatically flows at the set
pressure.
Use Gas/Air Set area of control range for set-
ting gas/air pressure (see Section 3-2).
4
Trouble Lights (see Section 4-2)
5
Power Light
6
Ready Light
SECTION 3 – OPERATION
2
9
Rear of Unit
Ready light comes On when unit is On to indi-
cate that all safety shutdown systems are
okay. If Ready light does not come On, check
trouble lights.
7
Pilot Arc Switch
Use switch to control pilot arc.
Place switch in Expanded Metal position for
continuous pilot arc. Use while cutting ex-
panded metals only.
.
The Expanded Metal position keeps the
pilot arc in the circuit at all times. Life of
5
6
7
consumables will be significantly re-
duced while in Expanded Metal mode.
Place switch in Tip Saver position to provide
pilot arc output for arc starting only. Use Tip
Saver position in most applications to length-
en the life of the torch and its consumables,
and to obtain maximum cutting performance.
After the cutting arc goes out, the torch
will automatically re-ignite the pilot arc if
the trigger is held down.
8
Torch Connection Receptacle
9
Power Switch
3
4
Ref. 196 174-A / Ref. 192441
OM-2220 Page 15

Publicité

Table des Matières
loading

Table des Matières