safety

building-in dimensions

132.5
If it not fitted with a plug (direct mains connection) or if the
plug is not located in an accessible area apply a double pole
switch in accordance with standards which assures the
complete disconnection of the mains under conditions
relating to over-current category III, in accordance with
installation instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
If the connection cable becomes damaged, it should be
replaced by the manufacturer's service department or by a
person with equivalent qualifications, in order to prevent
dangerous situations from arising.
Attention: Make sure that there is a sufficient supply of
fresh air, if an extractor hood and a heat source (e.g. gas
cooker) that both consume air from the same room, are
switched on at the same time. The maximum permitted
underpressure is 4 Pa.
599
125
125
97.7
510
installation
410
general
GB 13