PREPARATION
Verify operation/functionality of door control and operator prior to system installation.
Proper functionality of LZR-miscroscan system relies on proper installation and adjustment.
Installation with door system, as intended in UL 325, must be verified by installer.
Hub
1
Install hub in door header,
centered and in an easily
accessible location.
Sensors
1
Determine on which side
of door Door Loop will be
installed and cut to shortest
length to avoid loop in
detection zone.
4
Affix Door Loop to sensor
with Pass-Through Endcap
and three (3) screws
2
Page 4 of 12
Page 4 of 12
2
Plug System Harness into hub
port labeled System. Do not
plug in any other harnesses.
2
Take sensor to be mounted
on loop side and remove
Blank Endcap closest to door
hinge
NOTES:
1: For left sensor, remove left Blank Endcap or for right sensor,
remove right Blank endcap.
2: Pull extra Master Sensor Harness slack through Door Loop (away
from sensor) before tightening endcap screws.
.
IMPORTANT:
.
1
3
Route Master Sensor Harness
through Door Loop and plug
into sensor at closest port.
75.5753.10 LZR-MICROSCAN 20170310