SETUP
Be sure to walk test door after setup is complete and perform new learn anytime
1
Program hub according to
desired settings.
(Basic) items MUST be
programmed (pg 10).
4
Network icon will appear
for approximately five (5)
seconds.
6
Automatic teach in will begin
with door closed learn.
9
Door closing learn.
12
Once Teach In is complete,
LCD displays home screen,
Blue LED is off, and orange
LED is on
.
1
NOTES:
1: Verify Home Switch is "making/breaking" by observing orange LED on hub. Home Switch
should be set as sensitive as possible and break within a few degrees of door movement.
75.5753.10 LZR-MICROSCAN 20170310
75.5753.10 LZR-MICROSCAN 20170310
CAUTION - No safety present during learn cycle.
door operator, control, sensor, or hub is adjusted.
2
Return to home screen.
Menu 1
5a
"CLEAR AREA" will display
and countdown will begin.
Clear area around door on
both sides.
7
Door opening learn. Door will
open automatically.
10
After Teach In is complete a
floppy disk will be displayed.
Door Opening/Open/Closing Learn
TEACH-IN STAGE
Prior to Learn
blue flashing
Network Icon
blue flashing & orange solid
Clear Area
blue flashing & orange solid
Door Closed Learn
blue flashing & orange solid
blue flashing
Floppy Disk
blue flashing & orange solid
Hour Glass
blue flashing & orange solid
Learn Complete
3
Push and hold adjustment
knob for three (3) seconds,
until blue LED begins to flash.
5b
For dual egress doors, Push
Door icon will display. Push
right door (Door B) open at
least 10 degrees.
8
Door open learn.
11
Hour glass will be displayed
for approximately thirty (30)
seconds while all learn data
is saved.
HUB LED
green solid -> green flashing
green flashing -> red solid -> red/green flashing
orange solid
SENSOR LED
red/green flashing
red solid
red/green flashing
green flashing
green flashing
green solid
Page 9 of 12