BEA LZR-MICROSCAN Mode D'emploi page 5

Pour portes battantes automatiques
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Mounting height of 79" (min) to 98" (max) from finished floor to sensor LED
Sensors
1
sensor
DISTANCE FROM
mounting
TOP OF DOOR
1/8 "
wire passage
5/16 "
microscan
Scan for Product Info
*
*
*
spacer
mounting
1/8 "
MOUNTING HEIGHT RANGE: 75"-98"
(measured from finished floor to sensor LED)
Reference LZR-microscan User's Guide
75.5753 for full installation instructions
75.5754.04 20151124 LZR-microscan Mounting Template
Use Mounting Template to
position each sensor correctly.
Check for obstructions/
clearance.
4
Mount sensors (using ap-
propriate screws) by following
instructions on Mounting
Template.
7
Plug Master Sensor Harness
into hub port labeled Door A
Sensors
75.5753.10 LZR-MICROSCAN 20170310
75.5753.10 LZR-MICROSCAN 20170310
Refer to mounting template for full mounting instructions!
Do not apply sensor covers until system is fully operational.
Do not adjust tilt angle.
2
LEFT
MOUNT
MOUNTING INSTRUCTIONS
*
NOTES:
Mount sensors as close to top of door and as close to
hinge of door as possible.
Spacer required for applications with hardware
extending across width of door and protruding more
than 2 in.
For thin frame aluminum doors, mounting arm kit
may be used. When using mounting arm kit, do not
use this template.
STEP 1: SURVEY BOTH SIDES OF DOOR TO
DETERMINE APPROPRIATE MOUNTING
LOCATION (DISTANCE FROM PIVOT EDGE
AND DISTANCE FROM TOP OF DOOR),
TAKING INTO ACCOUNT FRAME CLEARANCE,
FINGER GUARD, DOOR ARM, ETC.
STEP 2: FOLD ALONG APPROPRIATE
HORIZONTAL AND VERTICAL LINES AND
ALIGN WITH PIVOT EDGE AND TOP OF DOOR
STEP 3: MARK AND DRILL THREE (3) HOLES
*
STEP 4: FLIP TEMPLATE AND REPEAT FOR
RIGHT SENSOR
* When using spacer, drill any two (2) spacer mounting
holes
and wire passage hole instead of sensor mounting
holes
.
When using optional mounting holes it may be
neccessary to remove end caps or sensor from base.
Align Mounting Template,
mark and drill holes
on both sides of door.
5
Plug in Slave Sensor Harness
at the upper most port on
sensor.
8
If necessary, repeat steps 1-7
for second door leaf using
hub port Door B Sensors.
IMPORTANT:
. Repeat
1
3
Run Slave Sensor Harness
through door.
6
Install Door Loop: drill 1/2"
passage hole in header and
jamb, route Master Sensor
Harness, install cap.
NOTES:
1. Spacer required for
applications with door