Technical Data Titrator Titroline ® 7500 Kf - Xylem SI Analytics TitroLine 7500 KF Mode D'emploi

Titrateur
Masquer les pouces Voir aussi pour SI Analytics TitroLine 7500 KF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

76
1.2 Technical Data Titrator TitroLine
CE sign:
ETL sign:
Country of origin:
The following solvents/titration reagents are allowed to be used:
− All common titration solutions.
− As reagent water and all non-aggressive non-organic and organic fluids are allowed. If using combustible
fluids fire please adhere to the Guidelines for Explosion Protection and Prevention of the chemical industry.
− For fluids with higher viscosity (≥ 5 mm
speed can be adjusted.
− Fluids with viscosity over 20mm
Measurement input:
* The measurement uncertainty of the sensor probe has to be taken into account as well.
Display:
Inputs:
Power supply:
RS232-C Interface:
Data bits:
Stop bit:
Start bit:
Parity:
Baud rate:
Address:
RS232-1
RS232-2
USB Interface:
EMC compatibility according to the Council Directive: 2004/108/EG;
applied harmonized standards: EN 61326-1:2006
Low-voltage directive according to the Council Directive 2006/95/EG
Testing basis EN 61 010, Part 1
Conforms to ANSI/ UL Std. IEC 61010-1
Certified to CAN/ CSA Std. C22.2 No. 61010-1
Testing basis EN 61 010, Part 1
Germany, Made in Germany
/s), lower boiling point or affinity to outgas, the filling and dosage
2
/s cannot be dosed.
2
Karl-Fischer (Dead-stop) connector for double platinum electrode
Polarisation voltage variably adjustable from 40 ... 220 mV.
Connector: 2 x 4 mm - sockets.
Measurement
range
0 ... 100
I [µA]
3.5 inches -1/4 VGA TFT display with 320x240 pixels.
Measurement input
Connection sockets: 2 x 4 mm)
power supply 90-240 V; 50/60 Hz, power input: 30 VA
Use the Power supply TZ 1853, Type No.: FW 7362M/12 only!
RS232-C interface separated galvanically through photocoupler
Daisy Chain function available.
adjustable, 7 or 8 Bit (default: 8 Bit)
adjustable, 1 or 2 Bit (default: 1 Bit)
static 1 Bit
adjustable: even / odd / none
adjustable: 1200, 2400, 4800, 9600, 19200 (Default 4800 baud)
adjustable, (0 to 15, default: 01)
for computer, input Daisy Chain
devices of SI Analytics, titrator TitroLine
- Burettes TITRONIC
- Balances of the types Mettler, Sartorius,
- Kern, Ohaus (for more, please contact SI Analytics)
- Exit Daisy Chain
2 x USB-type A and 1 x USB-type B
®
7500 KF
Display resolution
0,1
µA:
(Dead-Stop-) connector for double platinum electrode
6000/7000/7500,
500, TITRONIC
110 plus, TITRONIC
Status Nov.21
Measurement
accuracy* without
sensor probe
0,2 ± 1 Digit
universal,
th
2013

Publicité

Table des Matières
loading

Table des Matières