DANGER - ELECTRIC SHOCK RISK
Carefully read the instructions regarding use with diesel fuel.
USE WITH DIESEL FUEL
The pump must be installed under the
water level, the liquid must drop into
the pump body
CHAPTER 4

ELECTRICAL CONNECTION

WARNING
Ensure tension and frequency of electropump (read plate) and power supply are same.
DANGER - ELECTRIC SHOCK RISK
Installer must make sure that electric current network has ground wire conforming to current laws.
DANGER - ELECTRIC SHOCK RISK
Make sure that electric current network is provided with a high-sensitivity circuit breaker
∆=30 mA (DIN VDE 0100T739).
The single phase motors are protected from overloads by a thermal device installed in the winding.
The protection for the three phase motor must be installed by the user.
The following must be used as a conductor for the connection:
OUTDOORS: cable H07RN-F
IN INSIDE AREAS: cable H05RN-F or H07RN-F
For connecting single phase motors see Fig. 1
For connecting three phase motors see Fig. 2
For connecting double voltage single phase motors see Fig. 3
The pump should not run dry even
for short periods of time; in order to
do this check that the diesel fuel is
constantly being pumped during the
entire working period of the pump
As requested by the STANDARDISED
REGULATIONS we advise the user to
connect a recovery pipe with the drain
pipe in the lower part of the pump and
let it drain into a collection tank, in
order to prevent diesel fuel leakage if
the seal wears or breaks