7 INSTALLATION AND
COMMISSIONING
7.1 Safety Instructions
DANGER!
Danger of explosion!
•
The device is a sealed system. The unit must not be dismantled!
The following safety regulations must be observed::
•
The surface of the device may develop an electrostatic charge.
In areas with an explosion hazard, the surface of the units may only
be cleaned with a damp cloth!
•
Only permanently laid cables and wiring may be inserted.
•
The operator must provide suitable stress relief.
High voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
•
Work on the electrical system may only be carried out by qualifi ed
electricians!
•
Before starting work, switch off the power supply and secure to
prevent it being switched on again!
•
The connecting cables to the electromagnets must be secure,
and be laid so that they are adequately protected from mechanical
damage.
•
Observe the applicable accident prevention and safety regulations
for electrical devices!
01 ATEX 2194 X
WARNING!
Pressurised system!
Interventions in the pneumatic system represent an acute risk of
injury.
•
Work on the pneumatic system may only be carried out by qualifi ed
and instructed personnel using appropriate tools.
•
First switch off pressure before disconnecting lines and valves!
•
Observe the fl ow direction during installation!
•
Observe the applicable accident prevention and safety regulations
for pneumatic systems!
7.2 Montage
NOTES:
Installation in any position.
Preferably with solenoid system mounted at the top.
Activity
→
Clean the pipe runs
→
Installation in any position
→
Connect a dirt-trap (strainer)
upstream
→
Seal
- 15 -
Notes
-
Preferred direction with drive
mounted at the top
Note the direction of fl ow!
PTFE