TERMINAL BOARd CONNECTIONS
17-18 LC/ELS Courtesy light output 24 Vdc 15 W or output for a 12V
electric lock. Selection is carried out using dIP 6.
19
CMN common for all inputs and outputs.
20
LAMP 24 Vdc 25 W output for warning lights, intermittent
activation (50%), 12,5 W continuous activation.
21
Output powering external loads 30 Vdc
22
Controlled output, powering external loads 30 Vdc
23-24 CMN common for all inputs and outputs.
25-26 CMN common for all inputs and outputs.
27
FTCI (N.C./8.2 kΩ)
safety and control devices in input (photo-
(2)
cells invert the travel direction when an obstruction is detected).
Opening this contact will provoke a travel direction inversion
during closure due to the cutting in of the safety device.
28
TB (N.C./8.2 kΩ)
stop button input (The opening of this con-
(2)
tact interrupts the cycle until a new movement command is
given).
29
Td (N.O. contact) sequential command button input
30
CSP (N.C./8.2 kΩ)
safety edge input (The opening of this
(2)
contact interrupts the cycle both in the closing stage as well
as in the opening stage).
31-32 CH2 (N.O. potential free contact) for the second radio channel
33
Power output 0 Vdc for the digital safety edge
34
Power output 12 Vdc for the digital safety edge
35
CSPF Signal input from the digital safety edge
36
Outer conductor for radio receiver antenna
37
Inner conductor for radio receiver antenna (if an external
antenna is fitted use a coaxial type cable RG58 with an imped-
ance of 50Ω).
38
EMRG1
(N.O. contact) emergency manoeuvre input 1
(4)
39
EMRG2
(N.O. contact) emergency manoeuvre input 2
(4)
40
CMN common for the emergency buttons
Note
The total of the 2 external device outputs must not exceed 5W.
(1)
B1
Signal buzzer "via radio" mode
C1
Battery connection NiMH
C2
Transformer secondary connection
C3
Battery charger connection
CSER
Serial connection (only for diagnostics)
d1
Six-segment LEd display
dS1
Selection dip-switch
EM
Emergency manoeuvre enable
F1
Fuse 3,15AT (230 Vac circuit protection)
F2
Fuse 10A (motor power supply protection)
F3
Fuse 10A (motor power protection during battery operation)
Note
digit display (parameter "SC").
Note
function set the parameter "CSPF" to "1" in the menu.
Note
cut the two contacts "EM".
ALL UNUSEd NC CONTACTS MUST BE BRIdGEd and consequently
(1)
the security device test must also be deactivated (TFTC – dIP 5). If you
(1)
want to activate the FTCI test both the transmission and receiver parts
of the photocell must be connected to the binding post marked "CTRL
30 Vdc". If the test is active there will be a 1 second delay between the
command transmission and movement of the door.
Switch on the power and make sure that the indicator LEdS are in the
following condition:
- L1 Wrong battery connection
- L2 Power on
- L3 digital safety edge activity
- L4 Indicates transmitter code programming
- L5 Indicates active inverting photocells "FTCI"
- L6 Indicates active blocking button "TB"
- L7 Indicates active safety edge "CSP"
- L8 Indicates digital safety edge "CSPF"
(3)
- L9 Indicates active digital command "Td/CH1"
(3)
Note
(3)
Note
Note
Check that the activation of the safety devices (those which have
not been bridged) switch the corresponding LEdS off. If the green
power on LEd "L2" doesn't light up check the condition of the fuses
and the power cable connection at the transformer. If one or more
of the safety LEdS do not light up check the contacts of
security devices and check that the unused safety device contacts
have been bridged.
31
F4
F5
J1
J2
MM
P1
P2
P3
P4
P5
R1
23
The contact selection (N.C. or 8.2 kΩ) is carried out on the six
(2)
The special safety edge is disabled by default; to enable the
(3)
These inputs are disabled by default; to enable the functions
(4)
If this LEd is "lit" invert the battery power cables immediately.
(5)
This LEd is "lit" if the digital edge is connected and at rest.
(6)
The LEdS are "lit" when the relative safety device is inactive.
(7)
Fuse 4A (24V circuit protection during battery operation)
Fuse 4A (24V circuit protection)
Jumper enabling remote transmitter memorisation
Second radio channel selection jumper
Transmitter code memory module
Programming button (PROG)
Transmitter code cancellation button (dEL)
Transmitter code memorization button (MEMO)
dynamic button "Td"
Blocking button "TB"
Radio frequency module, 433 MHz for S449 transmitters
off
(5)
lit
off
(6)
off
lit
(7)
lit
(7)
lit
(7)
lit
(7)
lit
(7)
the relative