Alarm Management; Possible Causes - Palazzetti MULTIFIRE NICOLAS Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11

ALARM MANAGEMENT

11.1 DESCRIPTION OF MESSAGES
If a malfunction occurs, the following procedure is activated:
1) audible alarm (beep);
2) one of the following system LEDS come on:
3) if the problem concerns an error, the stove (if it is operating burning pellets) will switch off.
Pressing and holding the "cancel" button
ERROR/
WARNING CODE
Faulty control panel
E 0 0 1
E 0 0 2
Remote control signal communication error
E 0 0 4
Communication error
E 1 0 1
Failed ignition error
E 1 0 4
Brazier cleaning system jammed
E 1 0 5
Pellet probe malfunction
Temperature probe malfunction
E 1 0 6
Combustion chamber probe malfunction
E 1 0 7
Thermal cutout error
E 1 0 8
Pressure error or air control error
E 1 0 9
Flue gas temperature probe malfunction
E 1 1 1
Low pellet level ico
A 0 0 1
Scheduled maintenance warning ico s
A 0 0 2
A 0 0 6
Pressure sensor malfunction ico
A 0 0 7
--- -
Clean stove
--- -
Failed ignition error
cod. 004771980 - 09/2014 - Palazzetti - PN - Italy
USE AND & MAINTENANCE
DESCRIPTION
as i
as i
ar i
door or dra er ope
;
shows the error code on the display:

POSSIBLE CAUSES

Control panel fault
Control panel fault
Connection cable between board and control panel
interrupted or detached.
the error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
A foreign body is stopping the brazier cleaning
system from operating.
Pellet probe disconnected or faulty
Faulty air temperature probe
Faulty combustion chamber probe
Pellet tank overheating
Flue system dirty
Seals worn
Combustion air control system fault
Pellets running out
The stove periodically requires maintenance to be
The brazier door or ash drawer is open
Pressure sensor or board fault.
as i
system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets;
Incorrect burn pot position